Jdc-electronic-sa Geos 11 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Jdc-electronic-sa Geos 11 herunter. JDC Electronic SA Geos 11 User Manual [it] [en] [pl] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 2 - How to use this Manual

down to confirm your setting, the instrument is than activated and displays the standard screen. Remark: Setting the date and time may also be carried

Seite 3 - Table of Contents

state. Releasing the button during the countdown, brings back the default screen on the instrument. Basic Measuring Mode (Standard Screen) Reminder: A

Seite 4

Wind speed Measuring modes Instantaneous wind speed Maximum wind speed Average wind speed The measuring modes for the maximum and average w

Seite 5

The various measuring modes in relation to temperature are displayed on the middle block. In order to access a measuring mode, select (with the help o

Seite 6 - Introduction

Resetting the minimum and maximum humidity to zero Select the middle block and display the measuring mode that you wish to reset (it flashes), then pr

Seite 7

Select the lower block and display the measuring mode in relation to altitude (it flashes), then keep pushing the button down. starts flashing on th

Seite 8 - Analogue compass block

Select the lower block and display the measuring mode in relation to relative pressure (it flashes), then keep pushing the button down. starts flas

Seite 9 - Starting up the Instrument

Calibration of QFE pressure 17In aeronautics, the QFE pressure corresponds to the pressure on the landing runway (ground level), and is used as the b

Seite 10 - Switching the Instrument off

T 18here are two types of compass display: the compass block (always al display on the lower block. Select bargraph on visible) and digitthe lower bl

Seite 11 - (Standard Screen)

Flight Level Display In aeronautics. The Flight Level corresponds to an altitude expressed in hundreds of feet above the isobaric surface 1013.25 hPa,

Seite 12 - Measuring modes

English How to use this Manual We thank you for selecting a SKYWATCH® instrument. Even though this instrument was designed for ease of use in m

Seite 13

To display the special menu, press and hold simultaneously the and buttons, flashes on the upper block. When stops flashing, release the button

Seite 14 - Pressure

Date and Time Display 21upper block: day of the week large block : date middle block: month lower block: time and year + seconds on the bargraph O

Seite 15

The tendency is displayed using 63 values. The first 3 values show the variations in relation to the current pressure, the next 46 values in relation

Seite 16 - QFE height

The pressure displayed is that of 2 days earlier, i.e. the pressure recorded at noon (12:00) on April 28th. The instrument compares the last pressure

Seite 17 - Compass

Operation Pressing both the and buttons briefly at the same time launches the chronometer (brief display of the message ). This can be done from a

Seite 18 - Calibration

Magnetic Field in µTesla + Compass Heading Display This mode is displayed as follows: upper block: wind speed large block : heading in degrees middle

Seite 19 - Special Screens

button to select the direction of the adjustment ( increment, decrement), then set the value in degree of the declination with the help of the butto

Seite 20 - Enabling a Special Mode

Operation It is not possible to modify any data on the finesse screen. It is necessary for the impeller to rotate and there must be a drop in altitude

Seite 21 - Operation

Operation This type of memory displays all the recordings carried out manually. To record manually (from any screen, whether instrument turned on or o

Seite 22

Measurements Based on Selected Rate Display is displayed if the memory is empty (no recordings). The default screen is used to display the memory con

Seite 23

3Table of Contents How to use this Manual ... 2 Where to find information ...

Seite 24 - Density Altitude

History Display is displayed if the memory is empty (no recordings). The default screen is used to display the memory content. In the example shown o

Seite 25 - Heading

Storage 31The example shown opposite indicates that the instrument is in the storage state; the clock and sensors have stopped, and there is no autom

Seite 26 - Finesse

the button, then keep the button down ( flashes on the upper block). In the calibration mode (opposite screen), release the button. Set the time: p

Seite 27 - Manual Recordings

Other states The instrument features another two states: normal (turned on) and instantaneous (please refer to the Section entitled “Starting up the I

Seite 28 - Viewing

the screen displays the message , release the buttons and press the MOD () button down for 2 seconds to confirm. The instrument displays the messag

Seite 29

5. Check that the round seal is properly positioned in its groove, screw the lid back on using the 2 screws. Always pay attention to the polarity,

Seite 30 - States of the Instrument

2. While the instrument is on, press simultaneously on the 3 buttons and then release: the following indications will appear: (the instrument is in t

Seite 31 - Automatic Stop

Calibration of the Pressure Sensor This operation is reserved to those professionals who hold a highly accurate laboratory standard. The consequence

Seite 32 - Data transfer to a PC

38Humidity From a few seconds to several minutes depending on wind speed Pressure instantaneous Compass instantaneous Measuring range of sensors W

Seite 33 - General reset

39 LIMITED WARRANTY JDC ELECTRONIC SA extends a 12 months’ warranty over parts and labour for this instrument, effective from the date of purchas

Seite 34 - Instrument reset

4 Selecting the unit of measurement in relation to pressure ..15 Calibration of relative pressure (QNH) ... 15-16 QF

Seite 36 - Battery lifetime

5 Manual Recordings...27 Display...

Seite 37 - Technical Specifications

6Introduction Background information The GEOS N°11 is a high performance instrument used by professionals, the culmination of our 25 years of experi

Seite 38 - Miscellaneous

Description of Instrument Legend a wind sensor (impeller) h lid of battery compartment b protective sphere around the impeller i light emittin

Seite 39 - LIMITED WARRANTY

Description of the Sections of the Display Screen A Upper block B Large block C Middle block D Lower block E Analogue compass block Display

Seite 40

button is pressed briefly, the next block is selected in the following order: upper, large, middle, lower, upper, etc. If one (or several) special mod